Empire Lighting Resources Completes Retro-Fit For Carroll Tire Company’s Tampa, FL Warehouse
30/07/11
If you're new here, you may want to subscribe to my RSS feed. Thanks for visiting!

Before

After
Empire Lighting Resources recently completed a lighting retrofit for Carroll Tire Company’s 80,000 s.f. warehouse. Carroll’s primary light sources were from aging, energy consuming 458 watt metal halide fixtures, 300 watt incandescent fixtures and sky lights. As a result, the facility was grossly under lit, especially on cloudy days or when there was no sunlight. This problem was compounded by racking that is filled with black rubber tires which absorb light.
Empire Lighting resources provided a comprehensive lighting plan that provided significantly more light while not using excessive energy. Empire Lighting Resources used 8 lamp fluorescent Aisle Lighters with enhanced aluminum reflectors in the narrower aisles and 8 lamp Hi-Bay Reflector fixtures in the open areas. The installed fixtures all featured Empire Lighting Resources VIZ-A-LITE High Vision lamps.
The average energy savings will be approximately $4,700 per year, but more importantly, the facility is much brighter and Carroll Tire has happier and more productive employees.
Originally posted 2009-09-30 13:49:29. Republished by Blog Post Promoter


Before

After
Empire Lighting Resources, has completed the lighting retrofit for the 360,000 s.f. Pepperidge Farm, Inc. manufacturing plant located in Lakeland, FL. The energy savings initiative was the first for Pepperidge Farm which has nine production facilities throughout the United States.
The production area lighting consisted of 55% 458 watt high pressure sodium fixtures, 35% 455 watt metal halide and 10% 8′ fluorescent strip fixtures. All HID fixtures were replaced with 224 watt enclosed Hi-Bay fixtures utilizing Empire Lighting Resources VIZ-A-LITE High Vision fluorescent lamps. All existing 75 watt 8′ T12 cool white fluorescent lamps using 30 watt magnetic ballasts were replaced with 59 watt 8′ T8 VIZ-A-LITE High Vision lamps using normal ballast factor electronic ballasts. The result, an average of 52% energy savings per fixture and additionally, dramatic heat load reduction, while providing a tremendous improvement in light quality due to the increased CRI (color rendering index) caused by switching from the yellow tinted low CRI high pressure sodium lamps to the high CRI VIZ-A-LITE lamps.
In the office areas throughout the facility, all existing 2, 3, and 4 lamp cool white T12 fixtures as well as the 3 and 4 lamp T8 fixtures were retrofitted to 2 lamp T8 fixtures using VIZ-A-LITE High Vision lamps, enhanced aluminum reflectors and normal ballast factor electronic ballasts. The result, an average energy savings of 65% with again, a much improved quality of light. Additionally, all appropriate areas of the plant had occupancy sensors installed to provide additional energy savings.
Estimated annual savings in reduced energy demand will exceed $116,000 with an additional $73,000 in EPACT tax credits.
Pepperidge Farm will reduce CO2 emissions by 1,412 tons per year as well as a reduction of over 5.3 tons in SO2. This is the environmental equivalent of planting 224 acres of trees or removing 197 automobiles from the road, saving of over 100,813 gallons of gasoline and reducing oil demand by 2,400 barrels of oil.
Originally posted 2009-10-19 12:09:57. Republished by Blog Post Promoter

Before

After
Empire Lighting Resources has just completed an energy saving and lighting enhancement project at the Seldom Seen Gallery of Ft. Lauderdale, FL. Seldom Scene Gallery, chosen as “one of the top retailers of American craft” by Niche Magazine, was looking for ways to reduce energy costs while also increasing the image of the many items they present.
ELR replaced six existing uplight fan fixtures with nine Hi-Bay T8 fluorescent reflector fixtures with VIZ-A-LITE High Vision fluorescent lamps and electronic ballasts. The increase in overall brightness allowed for the removal of over 90 halogen spotlights, that were needed to light the store.
Due to the changes, Seldom Seen will consume almost 75% less energy to light their facility saving approximately $6,000 per year. The savings are derived from the combination of the energy-efficient fixtures and heat load reduction.
Originally posted 2009-10-06 12:24:26. Republished by Blog Post Promoter

Before

After
Empire Lighting Resources has just completed a lighting upgrade for All County Music of Tamarac, FL. The owner complained of high electric bills and that the store was dark and didn’t show his products in their best light.
Empire Lighting Resources replaced 27 outdated parabolic fixtures in the main store with energy efficient fixtures. Wattage consumption dropped from 192 to 80 per fixture while footcandle readings doubled. This was made possible by using ELR’s VIZ-A-LITE High Vision fluorescent lamps. In addition, Empire Lighting Resources upgraded an additional 60 existing four lamp fixtures using standard fluorescents and two magnetic ballasts in the repair and storage areas with two VIZ-A-LITE High Vision fluorescents and one electronic ballast.
By instituting these upgrades, ELR has reduced the lighting energy consumption, including heat load reduction used by All County Music by over 60%. This translates to a savings of over $4,000 per year.
The employees were thrilled with the new look of the store and the owner happily stated after completion, “you changed the look of my business from regular television to HD”.
Originally posted 2009-10-02 14:18:52. Republished by Blog Post Promoter